AEG HL 7275, DL 7275 installation instructions For the installer

Models: HL 7275 DL 7275

1 16
Download 16 pages 40.75 Kb
Page 4
Image 4

For the installer

When used as an extractor unit, the hood must be fitted with a 150mm diameter hose.

Attention: The hose is not supplied and must be purchased separately.

Should there already be a pipe of diameter 125 or 120 mm that ducts to the outside through the walls, it is possible to use the 150/ 125-120 mm reduction flange provided.

In this case the hood will be slightly noisier.

When installing the hood, make sure you respect the following minimum distance from the top edge of the cooking hob/ring surfaces:

electric cookers

500 mm

gas cookers

700 mm

The hood can be installed above these heights but for optimum performance it should be installed at the distance quoted for the appropriate heat source.

The national Standard on fuel-burning systems specifies a maxi- mum depression of 0.04 mbar in such rooms.

The air outlet must not be connected to chimney flues or combus- tion gas ducts. The air outlet must under no circumstances be connected to ventilation ducts for rooms in which fuel-burning appliances are installed.

The air outlet installation must comply with the regulations laid down by the relevant local authorities.

When the unit is used in extraction mode, a sufficiently large ventilation hole must be provided, with dimensions that are approxi- mately the same as the outlet hole.

National and regional building regulations impose a number of restrictions on using hoods and fuel-burning appliances connected to a chimney, such as coal or oil room-heaters and gas fires, in the same room.

Hoods can only be used safely with appliances connected to a chimney if the room and/or flat (air/environment combination) is ventilated from outside using a suitable ventilation hole approxi- mately 500-600 cm2 large to avoid the possibility of a depression being created during operation of the hood.

If you have any doubts, contact the relevant controlling authority or building inspector’s office.

Since the rule for rooms with fuel burning appliances is “outlet hole of the same size as the ventilation hole”, a hole of 500-600 cm2, which is to say a larger hole, could reduce the performance of the extractor hood.

47

Page 4
Image 4
AEG HL 7275, DL 7275 installation instructions For the installer