Installation on a not hard floor
When you install the appliance on a not
hard floor (wooden planks floor), put a
rigid support plinth under the appli-
ance feet to prevent the noise and the
vibration.
Assemble the plinth with a waterproof
wood panel (min. 15 mm thick) and at-
tach it to the beams of the floor with
minimum 2 screws.
The plinth must extend of some cm
more than the edges of the appliance.
We recommend you to install the appli-
ance in one of the corners of the room,
where the floor is more stable.
THE INLET HOSE
35O
35O
35O
45O
45O
45O
• C onnect the hose to the appliance.
Turn the inlet hose only left or right.
Loose the ring nut to set it in the cor-
rect position.
• Connect the water inlet hose to the
cold water tap with 3/4 thread.
CAUTION!
Make sure that there are no
leaks from the couplings.
Do not use an extension hose if
the inlet hose is too short. Con-
tact the service centre for the re-
placement of the inlet hose.
Water pressure
The appliance works correctly if the wa-
ter pressure is not less than 0.05 MPa
(0.5 bar).
If you can not connect the water inlet
hose to the cold water tap of the pri-
mary hydraulic system, connect it to
your domestic cold water storage sys-
tem.
Make sure not to have more than a dis-
tance of 5.02 m (16.5 ft) between the
appliance inlet hose and the bottom of
the water storage tank.
36