Lincoln Electric IM536-D manual Installation

Models: IM536-D

1 51
Download 51 pages 10.3 Kb
Page 9
Image 9

 

 

 

INSTALLATION

 

 

A-1

 

 

TECHNICAL SPECIFICATIONS – SP-125 Plus

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT – SINGLE PHASE ONLY

 

 

 

 

 

Standard Voltage/Frequency

Input Current

 

 

 

 

 

115V/60Hz

20 Amps - Rated Output

 

 

115V/60Hz

25 Amps - Maximum Output

 

 

115V/60Hz

15 Amps - CSA Rated output

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED OUTPUT

 

 

 

 

 

 

Duty Cycle

Amps

 

Volts at Rated Amperes

 

 

20% Duty Cycle – Rated DC Output

90

 

18

 

 

 

20% Duty Cycle - CSA Rated Output

63

 

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT

 

 

 

 

 

 

Welding Current Range (Continuous)

Maximum Open Circuit Voltage

 

Auxiliary Power

 

 

Rated DC Output: 0 - 90 amps

28

 

 

N/A

 

 

CSA Rated DC Output: 0 - 63 amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Useable Amperage Range

25 – 125 Amps

RECOMMENDED INPUT CABLE AND FUSE SIZES

 

 

 

 

 

 

 

 

Fuse or

 

 

 

Output Mode

Input Voltage

Breaker Size

Input Amps

Extension Cord

 

 

 

 

 

 

 

RATED

115V/60Hz

20 Amp

20

Three Conductor

 

 

 

 

 

#14 AWG

 

 

 

 

 

(2.1 mm2) or Larger

 

 

 

 

 

for up to

 

 

 

 

 

MAXIMUM

115V/60Hz

25 Amp

25

25 feet (7.6m)

 

 

 

 

 

Three Conductor

 

 

 

 

 

#12 AWG

 

 

 

 

 

CSA

115V/60Hz

15 Amp

15

(3.3 mm2) or Larger

 

 

 

 

 

for up to

 

 

 

 

 

50 feet (15.2 m)

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

Height

Width

Depth

Weight

12.0 in

9.75 in

16.5 in

54 Ibs

305 mm

248 mm

419 mm

24.3 kg

 

 

 

 

.

SP-125 PLUS

Page 9
Image 9