D-3

 

MAINTENANCE

 

 

 

 

 

COMPONENT REPLACEMENT PROCEDURES

CHANGING THE CONTACT TIP

1.Unplug or turn power switch to Off “O” position.

2.Refer to Figure D.2. Remove the gas nozzle from the gun by unscrewing counter-clockwise.

3.Remove the existing contact tip from the gun by unscrewing counter-clockwise.

4.Insert and hand tighten desired contact tip.

5.Replace gas nozzle.

CHANGING THE SP-125 Plus FOR USE WITH INNERSHIELD FLUX CORED WIRE

• Change The Contact Tip

1.Refer to Figure D.2. Remove the gas nozzle from the gun by unscrewing counter-clockwise.

2.Remove the existing contact tip from the gun by unscrewing counter-clockwise.

3.Insert and hand tighten the contact tip for use with 0.035” Innershield Flux Cored Wire.

4.Replace gas nozzle – The gasless nozzle may be used instead of the gas nozzle to give improved visi- bility of the arc.

CHANGING DRIVE ROLL

The drive roll, Figure D.1 Item 1, has two grooves; one for .023" – .025" (0.6 mm) solid steel electrode and a larger groove for .030" (0.8 mm) solid and .035" (0.9 mm) flux-cored steel electrode. As shipped, the drive roll is installed in the .023"-.025" (0.6 mm) position.

If .030"/.035" (0.8/0.9 mm) wire is to be used, the drive roll must be reversed as follows:

1.Turn the power switch to OFF (marked “O”).

2.Release the spring-loaded idle arm tensioner, Figure D.1 Item 2, and lift the idle roll arm, Figure D.1 Item 3, away from the drive roll.

3.Loosen the Phillips Head screw holding the drive roll onto the drive shaft.

SP-125 PLUS

CAUTION

When inching the welding wire, the drive rolls, gun connector block, and gun contact tip are energized relative to work and ground and remain energized for several seconds after the gun trig- ger is released.

4.Remove the drive roll, flip over and reinstall with the opposite groove closest to the gearbox.

NOTE: The stencil of the groove that you want to use is marked on the outside of the drive unit (when installed)

5.Push a length of straightened welding wire through the wire feeder guide tubes and reset the Phillips Head screw to secure the drive roll onto the shaft.

6.Reapply the spring loaded idle arm tensioner.

7.Turn the power “ON” (I) and check the drive roll for slipping when feeding wire. DO NOT OVERTIGHTEN - If necessary, tighten or loosen the spring loaded idle arm tension- er (2).

3

2

1

FIGURE D.1

Page 38
Image 38
Lincoln Electric IM536-D manual Changing the Contact TIP, Changing Drive Roll