More transient examples
The previous examples showed how the transient system can be used to control the output voltage amplitude. The transient system can also control output frequency, phase, waveform shape, voltage and frequency slew rates, offset voltage, and peak current limit. The following examples illustrate how the transient system’s Pulse mode can generate frequency, shape, phase, and voltage slew pulses.
Freq
FREQ TRIG
FREQ:M PULSE FREQ 60 FREQ:T 50
FREQ
Pulse |
|
WIDTH .1 | width |
| |
Trigger Control | Trigger |
|
INIT IMMED
Shift
Shape
Trigger
SHAPE:M PULSE SHAPE SINE SHAPE:T SQUARE
SHAPE TRIG
SHAPE
Pulse
WIDTH .05
Trigger Control
INIT IMMED
Shift |
| Trigger |
|
|
|
width
Trigger
Shift
Phase
PHASE:M PULSE PHASE 0 PHASE:T 180
PHASE TRIG
Pulse
PHASE
WIDTH .05
Trigger Control
|
|
|
| width |
INIT IMMED |
|
| ||
|
|
|
Shift
Voltage
Trigger
Trigger
VOLT:M PULSE VOLT 120 VOLT:T 150 SLEW:M PULSE SLEW 10000 SLEW:T 1000
SLEW TRIG | SLEW |
Pulse
WIDTH .1
Trigger Control
INIT IMMED
Shift |
| Trigger |
|
|
|
width
Trigger
14