Agilent Technologies 6843A, 6834B, 6814B, 6811B quick start

Models: 6834B 6843A 6814B

1 20
Download 20 pages 27.01 Kb
Page 18
Image 18
Manual background

Trigger

Trigger

Control

Trigger Function

Pressing the Shift Trigger key generates an immediate trigger

Trigger Control Functions

INIT:IMMED

Initiate trigger immediately

INIT:CONT ON OFF

Initiate trigger continuously

TRIG:SOUR BUS EXT

Select transient trigger source

TTLT IMM

 

DELAY <value>

Set trigger delay in seconds

ABORT

Abort all trigger sequences

SYNC:SOUR PHASE IMM

Select synchronous trigger source

SYNC:PHASE <value>

Set synchronous phase reference

Current

Voltage

Current Functions

CURR:LEV <value>

set immediate rms current limit4

CURR:PEAK <value>

set immediate peak current limit3

CURR:PEAK:T <value>

set triggered peak current limit3

CURR:PEAK:M FIXED STEP

select the peak current limit mode3

PULSE LIST

 

Voltage

Functions

VOLT <value>

set immediate ac output voltage4

VOLT:T<value>

set triggered output voltage4

VOLT:M FIXED STEP

select the voltage mode4

PULSE LIST

 

RANGE 150 300

set the voltage range2, 4

OFFSET <value>

set immediate dc offset voltage3

OFFSET:T<value>

set triggered dc offset voltage3

OFFSET:M FIXED STEP

select the dc offset voltage mode3

PULSE LIST

 

SLEW <value>

set voltage slew in V/sec4

SLEW:T<value>

set triggered voltage slew in V/sec4

SLEW:M FIXED STEP

select the voltage slew mode4

PULSE LIST

 

OFF:SLW <value>

set dc offset slew in V/sec3

OFF:SLW:T<value>

set triggered dc offset slew in V/sec3

OFF:SLW:M FIXED STEP

select the dc offset voltage slew

PULSE LIST

mode3

ALC INT EXT

select the voltage sense source

ALC:DET RTIME RMS

select the voltage sense detector3

Phase

Freq

 

Phase Functions

PHASE <value>

set immediate output phase4

PHASE:T <value>

set triggered output phase4

PHASE:M FIXED STEP

select the phase mode4

PULSE LIST

 

 

Freq Functions

FREQ <value>

 

set immediate output frequency

FREQ:T<value>

 

set triggered output frequency

FREQ:M FIXED STEP

 

select the frequency mode

 

PULSE LIST

 

 

SLEW <value>

 

set frequency slew in Hz/sec

SLEW:T<value>

 

set triggered frequency slew Hz/sec

 

SLEW:M FIXED STEP

 

select the frequency slew mode

PULSE LIST

 

 

 

Shape

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shape Functions

 

SHAPE

SINE SQUARE

set immediate shape

 

 

 

CSIN <user>

 

 

SHAPE:T

SINE SQUARE

set triggered shape

 

 

 

CSIN <user>

 

 

SHAPE:M

FIXED STEP

set shape mode

 

 

 

PULSE LIST

 

 

CLIP <value>

set clipping level

 

List

 

 

 

 

 

 

 

 

 

 

 

 

Pulse

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

List Functions

 

COUNT <value>

number of times a list repeats

 

DWEL:<index> <value>

list of output dwell times

 

FREQ:<index> <value>

list of output frequencies

 

FSLW:<index> <value>

list of output frequency slew rates

 

IPK:<index> <value>

list of output peak current limits3

 

OFFS:<index> <value>

list of dc output voltages3

 

OSLW:<index> <value>

dc offset voltage slew rate list3

 

PHASE:<index> <value>

list of output voltage phase

 

 

 

 

 

 

angles4

 

SHAP:<index> SINE SQUARE

list of output waveform shapes

 

 

 

CSIN <user>

 

 

STEP ONCE AUTO

set response of list to triggers

 

TTLT:<index> ON OFF

set trigger out pulse list

 

VOLT:<index> <value>

list of ac output voltages4

 

VSLW:<index> <value>

list of output voltage slew rates4

 

 

 

 

Pulse

Functions

 

WIDTH <value>

set the pulse width

 

COUNT <value>

set the number of output pulses

 

DCYCLE <value>

set the pulse duty cycle

 

PER <value>

set the pulse period count

 

qHOLD WIDTH DCYCLE

set parameter that is held constant

 

Index

 

pqIndex

 

 

Ù

 

 

Å

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pIndex Functions

These are Shift Index keys which are used to scroll through indexed functions. Press these keys to step through integers 0 through 50 for a harmonic list, or 0 through 99 for list points. Hold down these keys to rapidly access any harmonicqor list point.

pFunctions

These keys let you move through the choices in a command list. Command lists are circular; you can return to the starting position by continuously pressing either key.

 

This key applies to 3-phase ac sources only.

Phase

Pressing this key successively selects phase 1

Select

first, followed by phase 2, phase 3, and then all

 

 

three phases.

Output

This key toggles the output on and off. When off,

On/Off

the ac source output is disabled and the Dis

 

annunciator is on.

18

Page 18
Image 18
Agilent Technologies 6843A, 6834B, 6814B, 6811B quick start