Aiphone AXW-AVR Configuration Diagram, KBC FPVB1-AB1-IB2-ST, AX-DMor IE/IF-Series, Axw-Avt, Ax-Dv

Models: AXW-AVR AXW-AVT

1 13
Download 13 pages 5.74 Kb
Page 9
Image 9
KBC: FPVB1-AB1-IB2-ST

CONFIGURATION DIAGRAM:

AXW-AVT / AXW-AVR with KBC Networks (FPVB1-AB1-IB2-ST, FPVB1-AB1-IB2-SR), 1 of 2

Configuration Notes (1 of 2):

1.AX-series video door station connects to ‘DOOR’ input of AXW-AVT. Ensure that the “CCTV / DOOR’ switch on the AXW-AVT is in the ‘DOOR’ position.

*2. Alternatively, an IE/IF-series or AX-DM audio door may be used, along with 3rd party CCTV camera. Connect audio door station to ‘Door’ input (following the wiring method shown in the AX-series installation manual, pg. 12). Connect the camera to ‘Video In’ and put the ‘CCTV / DOOR’ switch in the ‘CCTV’ position.

Configuration Notes (1 of 2, continued):

4.When the SENSOR input is used, the door station will be turned on whenever the sensor device is activated (Normally Closed contact from 3rd party supplied device).

5.The RELAY output provides an optional Normally Open dry contact output which is activated whenever the AX-series door station is in use. This can be used to activate any device local to the AXW-AVT (DVR trigger, video switcher activation, local call indication, etc.).

3.

Connect the Call In / Call Out and Audio In / Audio Out connections on

6.

Configure AXW-AVT internal jumpers as necessary (see Pg. 21).

 

 

the AXW-AVT to the Meridian fiber transmitter module (as detailed at

 

 

KBC: FPVB1-AB1-IB2-ST

 

 

 

 

 

right, Fig. 1). For complete pin definitions, consult the Meridian

 

 

 

 

 

 

 

installation document.

 

 

 

 

 

 

 

 

 

 

 

AX-DM or IE/IF-Series

 

AXW-AVT

PS-2420UL

 

 

 

 

 

 

 

 

Audio Door Station

 

24V

 

 

A+ A- GND A+ A- GND

 

 

 

 

 

 

 

+

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

-

 

 

 

 

 

 

 

 

 

 

RELAY

Normally Open contact for

 

V1

AUDIO 1 AUDIO 2

C1

C2

C3

C4

 

 

 

NO

remote device activation

 

 

 

 

NO

 

 

 

 

(i.e. video switcher, DVR, etc.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SENSOR

Normally Closed input for remote

 

 

 

 

 

 

 

 

 

 

NC

 

 

 

 

 

 

 

 

 

 

NC

activation

 

 

 

 

 

 

 

 

 

 

CALL IN

(i.e. motion sensor, loop detector, etc.)

 

 

 

 

 

To Door

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+

 

 

 

 

 

 

 

 

 

 

-

 

 

 

 

 

 

Release

 

CCTV Camera

 

CALL OUT

 

 

 

 

 

 

 

 

 

+

 

 

 

 

 

 

 

 

75 Ohm, 1V Peak-to-peak

 

-

 

 

 

 

 

 

 

 

(Independently powered)

 

AUDIO IN

 

 

 

 

 

 

 

 

 

 

 

+

 

 

 

 

 

 

 

 

 

 

 

-

 

 

 

 

 

 

 

 

 

 

*

AUDIO OUT

 

 

 

 

 

 

 

 

 

 

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

 

 

 

 

 

 

 

 

AX-DV

DOOR

CAT-5e

VIDEO IN

Coax

VIDEO OUT

Coaxial Video Cable

Please Note:

Only information pertaining to the connection and operation of the AXW-AVT / AXW-AVR and listed 3rd party devices interfacing with it are included here. Aiphone is not responsible for attempts to connect the AXW-AVT / AXW-AVR to untested 3rd party transmission hardware. Consult the installation manual for the 3rd party device being utilized

for further information regarding physical mounting, base functionality, power requirements,

etc. For the most up-to-date compatibility information, please consult http://

www.aiphone.com or contact Aiphone Technical Support.

 

For complete AX system installation, wiring, and programming information, please consult the AX Installation Manual (included on CD with AX Central Exchange Unit, or

Pg. 15 available at http://www.aiphone.com).

Pg. 16

Page 9
Image 9
Aiphone AXW-AVR Configuration Diagram, KBC FPVB1-AB1-IB2-ST, AX-DMor IE/IF-Series, Axw-Avt, Audio Door Station, Ax-Dv