4-2

 

 

 

 

 

 

 

 

 

 

 

 

a

 

b

c

 

 

 

 

 

 

 

e

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1P

 

 

 

 

 

 

 

 

 

 

 

NP

 

GH-1AD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IN

OUT

 

 

 

 

 

 

 

 

 

 

R1R2 R1R2 C CE

K KE

 

 

 

 

 

 

 

 

1P

 

 

 

 

 

 

 

 

 

 

 

NP

 

 

 

 

 

 

 

 

 

 

 

R1, R2

 

 

 

 

 

 

 

 

SW1

 

 

 

 

 

 

 

 

 

 

c

A

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GH-1KD

 

 

 

 

 

 

 

 

 

 

 

 

 

IN

OUT

IN

OUT

 

 

 

 

 

 

 

 

B1B2 B1B2

R1R2 R1R2 C CE

K KE

 

 

 

 

 

 

 

1P

1P

[2]

 

 

 

 

 

 

 

NP

NP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K

KE

 

 

 

 

 

 

SW1

B

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GH-1KD

 

 

 

 

IN

OUT

IN

OUT

 

 

 

 

 

 

 

 

B1B2 B1 B2

R1 R2 R1 R2 C CE

K KE

 

 

 

 

 

 

 

 

 

 

 

[2]

 

 

 

 

 

 

[1]

SW1

 

1P

1P

 

 

 

 

 

 

GH-1KD

B

 

 

 

 

 

 

A

NP

NP

 

 

 

 

 

 

 

 

 

 

 

 

SW1 A B Do not

remove the

wires (For end users)

 

 

 

 

 

 

 

IN

OUT

 

0.65 10 9

 

 

 

 

 

 

 

R1

R2

R1

R2

C CE

K KE

 

IN

OUT

IN

OUT

 

 

 

 

 

 

 

 

B1B2 B1 B2

R1 R2 R1 R2 C CE

K KE

 

 

 

 

 

 

GH-VBC

 

 

 

 

[2]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b GH-BC

1P

 

 

 

 

 

 

 

 

 

 

NP

 

 

 

[3]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GH-RY

 

 

 

 

1P

 

 

 

 

 

 

 

 

 

 

 

NP

 

 

 

 

 

 

 

 

 

 

 

 

[4]

 

 

B

AC

 

 

 

 

 

4-1

Standard System (1)

[1]Entrance Station

[2]Door release timer (set to "M" at time of shipment)

Set the duration for the door release function when the door release button is pressed.

[0.5] - [20]: 0.5 secs - 20 secs

[20]- [M]: Activates while the button is pressed.

[3] Setting switch (GH-DA)

SW2: 1: Setting switch for camera entrance station monitoring function (set to OFF at time of shipment)

ON (Up): Monitored.

OFF (Down): Skipped at time of entrance station monitoring.

SW2: 2 - 4: Entrance station number setting switch (set to #1 at time of shipment)

[4]External relay GH-RY For details, see 4-5.

[5]Door release relay contact

Less than AC/DC 24 V, 4 A (resistance load)

[6]Security guard station GH-MK

[7]Setting switch (GH-MK)

SW1: 1: Password reset switch

Set the password reset switch to ON for 2 seconds or more during standby will reset the password (set to "1111" at time of shipment).

SW1: 2, 3: Unused switch

SW1: 4: Security guard station number setting switch (set to #1 at time of shipment)

[8]Doorbell button

[9]Power supply adapter PS-2410LC, PS-2410LD, PS-2410DIN

[10]Video bus control unit GH-VBC (SW: STD)

[11]Video bus control unit GH-VBC (SW: EXP)

To use GH-VBC as an extension adapter, set the setting switch to "EXP."

[12]Bus control unit GH-BC

[13]Distribution terminal (junction): sold separately

NP: Non-polarized

4-2

Standard System (2) Station-to-Station Wiring

[1] Residential station GH-1KD, GH-1AD

There can be a maximum of 25 stations per system.

For the terminating residential station, set the setting switch to "A". [2] Short lead

To use the emergency alarm switch (see 11-7 for details), disconnect the short lead and connect the switch.

[3]External relay GH-RY For details, see 4-5.

[4]Doorbell button

1. Do not mix station-to-station wiring with homerun wiring. 2. Station-to-station wiring is not possible for GH-1MD.

NP: Non-polarized

- 19 -

Page 19
Image 19
Aiphone GH series operation manual Standard System 2 Station-to-Station Wiring