Description

Serial control

This connection is for use by authorised specialist staff only!

NOTE

Standard: RS-232

Use: connect to PC, firmware update, external control

Figure 9: RS232 socket

The serial control takes place using a 9 pin sub-D socket with the label "RS232". This socket allows you to perform software updates.

The pin assignment is as follows:

Pin

Function

1

N.C.

2

RxD

3

TxD

4

N.C.

5

GND

6

GND

7

N.C.

8

N.C.

9

N.C.

Earth/Ground connection

Figure 10: Phoenix terminal

A phoenix terminal connects the case with the 0 V potential of the power supply.

Only bridge the 0 V potential with the grounding (factory setting) or connect it to the central system ground, as otherwise the phantom power has no reference point and will not function.