Installation/Operation Supplement

Position and Level the Tumbler

WARNING

To reduce the risk of severe injury, clearance of tumbler cabinet from combustible construction must conform to the minimum clearances.

W056

 

3

4

 

 

 

2

5

 

 

 

 

6

1

 

 

7

 

TMB2021N

25, 30, 35 AND 55 POUND

 

 

 

 

 

3

1

 

 

 

 

4

 

2

5

 

 

6

7

T30 AND T45

TMB2110N

NOTE: Shaded areas indicate adjacent structure.

113 mm (0.5 in.) recommended between machines for removal or installations.

2Allow 51-102 mm (2-4 in.) opening at top of machine to aid in removal or installation. A removable trim piece may be used to conceal the opening; zero clearance allowed for trim.

3102 mm (4 in.) Maximum Header Thickness

4305 mm (12 in.) Minimum Clearance

5610 mm (24 in.) minimum, 914 mm (36 in.) recommended for maintenance purposes.

6Provision for make-up air: Minimum 709 cm2 (110 in.2) required per tumbler for 25 and 30, 928 cm2 (144 in.2) for 35 and 55 pound models, 1418 cm2 (220 in.2) for T30 models and 1856 cm2 (288 in.2) for T45 models. Location for reference only. May be anywhere behind tumbler.

6 mm (0.25 in.) recommended for removal or installation purposes, zero clearance allowed.

Figure 1

14

© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT

70392201 (EN)