Installation/Operation Supplement
Ignition Control Operation
Flame Probe TestsUnexpected Presence of Flame
The Unexpected Presence of Flame test is performed when no flame is expected. Failure of this test results in the ignition control entering Lockout Mode with the Diagnostic LED displaying Error Code 3.
Flame Monitoring
During the Flame Monitoring test, the flame is checked to ensure the gas is being burned when the gas valve is on. Failure of this test will result in the ignition control entering Lockout Mode with the Diagnostic LED displaying Error Code 3.
The Diagnostic LED or DGN LED is located by the power connector on the ignition control. Refer to Figure 21. The Diagnostic LED will indicate the status of the ignition control. Refer to Table 3.
LED Color | Description |
|
|
Initialization | |
|
|
Green | Standby / Normal Operation |
|
|
Red | Fault Indication Code |
|
|
| Table 3 |
The Diagnostic LED will flash error codes one half second on and one half second off. Error codes are separated by a one second pause before the code is repeated.
Error |
|
|
| DGN LED status |
|
| Fault Type | |||||
Code |
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
1 |
| Red |
|
| Ignition Control Internal Failure | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
2 |
| 2 Red Flashes |
|
| Gas Valve Not Connected | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
3 |
| 3 Red Flashes |
|
| Ignition/Flame Sense Failure | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
4 |
| 4 Red Flashes |
|
| Reset Switch is Shorted | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
5 |
| Slow Red and Green Flashes |
|
| Low Voltage Detection | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
6 |
| Fast Red and Orange Flashes |
|
| Ignition Control is in Reset Delay | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
TMB2176N
1Diagnostic (DGN) LED
Figure 21
28 | © Published by permission of the copyright owner – DO NOT COPY or TRANSMIT | 70392201 (EN) |