Installation/Operation Supplement
2
1
SUPPLY
| 4 |
| 10 |
9 | 3 |
| |
| 5 |
8 |
| 6 | 4 |
|
| ||
|
|
| |
|
|
| RETURN |
7 |
|
|
|
6 | 5 10 |
|
|
|
| T473I | |
|
|
| T473I |
Note: Refer to Table 2 for sizing of steam lines. Piping must also be sized accordingly for length of runs, and number of elbows.
1 | Steam Coil | 6 | Trap with |
2 | 305 mm (12 in.) Riser | 7 | Vacuum Breaker (Optional) |
3 | Condensate Return Line from Supply Line | 8 | 457 mm (18 in.) Drop |
4 | 9 | Solenoid Valve (Supplied with machine) | |
5 | Check Valve | 10 | Union |
Figure 2
Model | Steam Pressure | Minimum Pipe Diameter | Steam Trap Size * | |
PSI (bar) | (Pounds Condensate/Hour) | |||
|
| |||
|
|
|
| |
25/30 Pound | 3/4 in. NPT | 134 | ||
|
|
|
| |
T30 | 3/4 in. NPT | 110 | ||
|
|
|
| |
35 Pound | 3/4 in. NPT | 166 | ||
|
|
|
|
* Based on 100 PSI.
Table 2
22 | © Published by permission of the copyright owner – DO NOT COPY or TRANSMIT | 70392201 (EN) |