Installation/Operation Supplement

2

1

SUPPLY

 

4

 

10

9

3

 

 

5

8

 

6

4

 

 

 

 

 

 

 

 

RETURN

7

 

 

 

6

5 10

 

 

 

 

T473I

 

 

 

T473I

Note: Refer to Table 2 for sizing of steam lines. Piping must also be sized accordingly for length of runs, and number of elbows.

1

Steam Coil

6

Trap with Built-In Strainer

2

305 mm (12 in.) Riser

7

Vacuum Breaker (Optional)

3

Condensate Return Line from Supply Line

8

457 mm (18 in.) Drop

4

Shut-Off Valve

9

Solenoid Valve (Supplied with machine)

5

Check Valve

10

Union

Figure 2

Model

Steam PressureMinimum Pipe DiameterSteam Trap Size *
PSI (bar)(Pounds Condensate/Hour)

 

 

 

 

 

 

25/30 Pound

15-100 (1-6.9)

3/4 in. NPT

134

 

 

 

 

T30

15-100 (1-6.9)

3/4 in. NPT

110

 

 

 

 

35 Pound

15-100 (1-6.9)

3/4 in. NPT

166

 

 

 

 

* Based on 100 PSI.

Table 2

22

© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT

70392201 (EN)