Programming

 

Table 4 (Continued)

Pause 5 seconds, then

Display shows “rEv”

Reverse wash speed –

 

Outputs: Motor operates wash speed reverse; drain closed

2 minutes, then pause

 

several seconds before

 

entering drain (next step)

 

Drain (cannot advance to

For 2 speed models: Display flashes “drAI”/ “For” (keypad RINSE LED on)

spin here)

For variable-speed models: Display flashes “drAI”/ “For” while operating in low speed

 

forward; then flashes “drAI”/ “dISt” while operating at distribution speed.

 

If balance fails, repeats the “drAI”/ “For” then “drAI”/ “dISt” sequence above and balance

 

indicator is on during “drAI”/ “For” message (rebalance attempt). Tries up to 10 times in

 

TEST cycle then aborts test cycle.

 

Outputs: Drain closed for first part of step (less than 20 seconds), then drain off.

 

2 speed models: Wash speed forward

 

Variable-speed: Forward during “drAI”/ “For”; distribution during “drAI”/ “dISt”.

Spin – 3 minutes

For 2 speed models: display shows “SPn” (keypad SPIN LED on)

 

For variable-speed models: display shows “SPn1” (keypad SPIN LED on)

 

Outputs: Spin (low spin for variable speed-see motor chart below)(*)

 

 

Highest Spin speed

For 2 speed models: this step is skipped (goes to coast, the next step)

(variable-speed models

For variable-speed models: display shows “SPn2” (keypad SPIN LED on)

ONLY) – 3 minutes

 

Outputs: Highest spin speed selected (see motor chart below)(*)

 

Coast

Displays “SdLY” (spin delay coast)

 

 

 

Outputs: all off

Stop routine.

Display shows “01” (1 minute remaining). Agitates briefly then unlocks the door, shows

 

“dOnE” while sounding the buzzer 10 seconds; “dOnE” shows for 20 more seconds.

 

(DOOR LED on while showing “dOnE”, meaning “door ready to open”).

 

Table 4

(*) For certain 125 models, the RPM may display.

NOTE: ON appears ONLY where motor control outputs are on (otherwise they are off). Outputs referenced are on control unit fuse board. Outputs are as labeled on the fuse board.

Motor Speed Chart

 

Variable-speed motor control outputs –

2 speed motor outputs

 

applies only for variable-speed models

 

 

 

 

STF

STR

RH

RM

RL

Fwd

Rev

Spin

 

 

 

 

 

 

 

 

 

Motor off (no rotation)

 

 

 

 

 

 

 

 

Wash speed forward

ON

 

 

ON

 

ON

 

 

Wash speed reverse

 

ON

 

ON

 

 

ON

 

 

 

 

 

 

 

 

 

 

Distribution (variable-speed ONLY)

ON

 

ON

 

 

NA

NA

NA

Spin (low spin speed “SPn1” for variable-

ON

 

 

ON

ON

 

 

ON

speed)

 

 

 

 

 

 

 

 

Highest spin (“SPn2” – variable-speed ONLY)

ON

 

ON

 

ON

NA

NA

NA

 

 

 

 

 

 

 

 

 

NA – Not Applicable

 

 

 

 

 

 

 

 

Table 5

NOTE: For variable-speed machines smaller than

C80, SPn1 and SPn2 are not the same speed.

30

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F232157