Safety Information

AC Inverter Drive

Machines equipped with the AC inverter drive require special attention with regard to the operating environment.

An especially dusty or linty environment will require more frequent cleaning of the AC inverter drive cooling fan filter and of the AC inverter drive itself.

Power line fluctuations from sources such as uninterruptible power supplies (UPS) can adversely affect machines equipped with the AC inverter drive. Proper suppression devices should be utilized on the incoming power to the machine to avoid problems.

A clean power supply free from voltage spikes and surges is absolutely essential for machines equipped with the AC inverter drive. Nonlinear inconsistencies (peaks and valleys) in the power supply can cause the AC inverter drive to generate nuisance errors.

If voltage is above 240 Volt for 200 Volt installation, ask the power company to correct. As an alternative, a step-down transformer kit is available from the distributor. If voltage is above 480 Volt for 400 Volt installations, a buckboost transformer is required.

Sufficient space to perform service procedures and routine preventive maintenance is especially important for machines equipped with the AC inverter drive.

This manual is designed as a guide to operating and maintaining the Pocket Hardmount washer-extractor equipped with the AC inverter drive.

NOTE: All information, illustrations, and specifications contained in this manual are based on the latest product information available at the time of printing. We reserve the right to make changes at any time without notice.

8

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F232201