Operation

 

Display Interpretations

 

 

W6

Wash 6 (extra low agitation)

 

 

W7

Wash 7 (no agitation, drain 1 open, no

 

refill)

 

 

WD

Wash drain step – shortest drain time. Use

 

only if not followed by a spin step. Drain 1

 

open, no rotation.

 

 

WF

Warm flush

 

 

WH

Warm fill to high level

 

 

WM

Warm fill to medium level

 

 

WL

Warm fill to low level

 

 

WO

Warm fill to overflow level

 

 

WR

Warm rinse

 

 

Left dot–poor balance condition

 

 

Second dot from left–door lock switch

 

 

Third dot from left–Program Mode

 

 

Fourth dot from left–high level reached

 

 

Fifth dot from left–medium level reached

 

 

Right dot–low level reached

 

 

EXISTS

Cycle already in memory

 

 

EDIT?

Do you want to edit the cycle?

 

 

TEMP

Over-temperature-limit condition

 

 

OVERHT

Open or shorted temperature input circuit

 

or temperature out of computer’s allowable

 

limits

 

 

WATER

Water in washer-extractor at end of cycle

 

 

°FAR

Temperature in degrees Fahrenheit

 

 

°CEN

Temperature in degrees Centigrade

 

 

MANUAL

Manual Mode enabled

 

 

NO MAN

Manual Mode disabled

 

 

1DRAIN

One drain capability selected

 

 

2DRAIN

Second independent drain enabled (via

 

Auxiliary 2 output–precludes control of

 

recirculation pump via Auxiliary 2, if

 

selected). This should not be confused with

 

the “dual drain” option.

 

 

ADV

Advance (skip steps) feature enabled

 

 

 

Table 1

 

Display Interpretations

 

 

NO ADV

Advance feature disabled

 

 

WET CL

Wet clean function for Auxiliary 1 output

 

(1/2 wash speed) and Auxiliary 2 output

 

(recirculation pump) enabled (see

 

“2DRAIN.”)

 

 

NO WCL

Wet clean function for Auxiliary 1 and 2

 

disabled (Auxiliary 1 and 2 are timed

 

outputs.)

 

 

S BAL

“Short” balance routine–active only if

 

inverter drive load balance sensing is

 

utilized.

 

 

L BAL

“Long” balance routine–active only if AC

 

inverter drive load balance sensing is

 

utilized.

 

 

DRTEMP

Temperature is above 160°F in drain to

 

reuse tank A or B step.

 

 

BAL DR*

Cycle aborted due to extreme out-of-

(flashing at

balance condition or door is unstable.

the end of

 

cycle)

 

 

 

 

Table 1

* Design U6 and greater models

16

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT