Operation
Error Recovery Routine
When the control detects an error, it will stop running the current step and display a message to indicate what type of error was found:
•“FILL” indicates that the
•“EMTY” indicates that the
•“TEMP” indicates that the temperature sensor has recognized a temperature above the programmed value.
•“MEMR” indicates that the control has detected a problem with the cycle information. The cycle must be edited.
•“WATER” indicates that the
•“DRTEMP” indicates that the
All outputs remain off while the message displays, and the door cannot be unlocked.
NOTE: The
Each of these errors is considered to be recoverable. The operator has two minutes to respond to the error condition (except in the case of “WATER”). During this time, the control will turn the signal (buzzer) relay on and off at the rate of one second on and one second off to alert the operator to the error condition. The
NOTE: The “TEMP” alarm can be recovered only after the temperature falls below the alarm level.
Certain error conditions are considered to be non- recoverable:
•If the door opens during a cycle, the control will display “DOOR.” The operator must close the door.
Then, after the control has detected that the door is closed, it will automatically abort the cycle and go to the normal stop routine.
•“OVERHT” will be displayed when the control detects an open or shorted temperature input circuit or temperatures are outside of the washer- extractor’s allowable limits. Contact a service technician.
24 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | F232201 |