Out of balance switch

1/2

1/2

 

Window

1/3

Probe

 

 

Label 16

6

The out of balance switch is mounted on the solid part of the machine.

There is a window around the probe of the out of balance switch that is mounted on the movable part of the machine.

When the machine goes out of balance by overloading or uneven distribution of the linen, the out of balance switch will interrupt this action to prevent damage to the machine.

Important

To guarantee good functioning, the probe should be centered horizontally and vertically at 1/3 from the bottom of the out of balance window (when machine drum is empty). (See Label 16)

Opening the door in case of an emergency

To open the door in case of an emergency (deficiencies, etc.), remove the lock cover plate (A). Subsequently, insert a screwdriver from the left-hand side behind the lock mechanism (B) and push back the black handle (C) while opening the doorhandle.

A

Important

Before opening the door, be sure there is no water left in the tub and that the drum has come to a complete stop.

BCC

40

Page 40
Image 40
Alliance Laundry Systems HF900, HF575, HF455, HF730 Out of balance switch, Opening the door in case of an emergency