Label 5
Label 6
4
35
The liquid soap connection consists of 8 connections for liquid soap
(See Label 5).
The central opening is used for ventilation.
Liquid soap connection (option)

Connection of the liquid soap hoses

WARNING
Dangerous Chemicals. May damage eyes and skin. Wear eye and
hand protection when handling chemicals; always avoid direct
contact with raw chemicals. Read the manufacturer’s directions for
accidental contact before handling chemicals. Ensure an eye-rinse
facility and an emergency shower are within easy reach. Check at
regular intervals for chemical leaks.
CAUTION
Drill out plugs and nipples before making supply hose connection.
Failure to do so can cause buildup of pressure and risk a tubing
rupture.

Electrical connection of the liquid soap pumps

On machines equipped with a liquid soap connection, connect the wires directly on
the print board next to the ground wire connection (option). Connect as indicated on
the wiring diagram.
The two connectors on the right give a tension of 220V ~ (max. 4A) which can
be applied to drive 220V ~ soap pumps. If more than 4A is required, an external
tension will have to be used. 6 connections have been provided, of which one (S6)
can be used to drive a waterprooî‚¿ng pump (e.g. for rain coats, etc.). (See Label 6)