Step 3: (Gas Dryer ONLY)
Connect Gas Supply Pipe
For further assistance, refer to Section on Gas Requirements.
1.Make certain your dryer is equipped for use with the type of gas in your laundry room. Dryer is equipped at the factory for Natural Gas with a 3/8" NPT gas connection.
2.Remove the shipping cap from the gas connection at the rear of the dryer. Make sure you do not damage the pipe threads when removing the cap.
3.Connect to gas supply pipe.
4.Tighten all connections securely. Turn on gas and check all pipe connections (internal & external) for gas leaks with a
5.For L.P. (propane) gas connection, refer to Section on Gas Requirements.
NEW
STAINLESS STEEL
FLEXIBLE
CONNECTOR
USE ONLY
IF ALLOWED
BY LOCAL
CODES (Use
Design A.G.A.
Certified
Connector)
3/8" NPT
GAS CONNECTION
BLACK IRON PIPE Shorter than 20' (6.1 m) - use 3/8" pipe Longer than 20' (6.1 m) - use 1/2" pipe
1/8" NPT
PIPE PLUG
(For checking
inlet gas pressure)
EQUIPMENT
VALVE Install within
6' (1.8 m) of dryer
D233IE3D
6 | 504607 |