Installation

Machine Foundation

The machine must be secured to a foundation or floor of adequate construction. Detail must be stressed with all foundation work to ensure a stable unit installation, eliminating possibilities of excessive vibration. The machine must be anchored to a smooth level surface so that the entire base of the machine is supported and rests on the mounting surface. Do not support the machine on only four points. Anchor bolts must be a minimum of 3/4 inch diameter, grade 2. Refer to Mechanical Installation.

A base designed to elevate the UW50 to a comfortable and more accessible height for loading and unloading laundry may be used. Care must be exercised in the design of such a base due to the force exerted by the machine during extract (222 Gs).

Static and dynamic loads on the floor or foundation are shown in Table 2. This table can be used as a reference when designing floors and foundations.

NOTE: Machine must be installed on concrete floor that is a minimum of 12 inches thick. Do not mount on wooden floors. Do not install above ground floor. Floor must be solid.

Floor Load Data

 

Maximum Floor Load

Frequency of

Combined Static and Dynamic

Mounting Bolt Size

 

at Extraction Speed

Dynamic

 

Floor Load

 

Model

Load

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

lbs.

kN

Cycles (Hz)

lbs.

kN

lbs./

kN/m2

inch

mm

 

 

 

 

 

 

sq. ft.

 

 

 

UW50-4

1575±2220

7.0±9.9

11.67

3795

16.9

425.9

20.39

3/4

M20

 

 

 

 

 

 

 

 

 

 

Table 2

10

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT