Mechanical Installation
A proper foundation is absolutely necessary for the
A bolt kit is available as an option consisting of eight 3/4 inch bolts, 8 inches long, which should be imbedded in a reinforced concrete floor that is a minimum of 12 inches thick.
0.75 in. | 1 |
| |
(19 mm) | 2 | ||
|
3
2 in.
(51 mm)
8 in.
(203 mm)
4
5
TYPICAL METHOD OF MOUNTING USING
INDIVIDUAL MOUNTING BOLTS
PHM178N
NOTE: Existing floor must be a minimum of 12 inches thick.
1Machine Base
2Piece of Angle Welded to Bolt to Prevent Turning
3Grouting – 1/2 in. Thick
43/4
5Conical hole drilled or chiseled into existing floor. Fill with “Sulfaset” bolt or equivalent.
Figure 1
The threaded end of the bolts should extend 2 inches above the surface of the floor. Refer to Figure 3 for the location of these bolts. A bolt locator fixture (base frame), consisting of a rigid welded assembly made of reinforcing rod welded to the eight 3/4 inch bolts which may be embedded in the concrete as one piece is also available as an option. Refer to Figure 2. Be sure the bolt threads also extend 2 inches above the floor.
Installation
1
2
3
4
5
PHM179N
TYPICAL METHOD OF MOUNTING
USING BASE FRAME
PHM179N
1Machine Base
2Bolt Threads
3Grouting – 1/2 in. Thick
4Reinforcing Rod
53/4 in. x 8 in. Bolt
Figure 2