Installation

Grounding

For personal safety and proper operation, the machine must be grounded in accordance with state and local codes. If such codes are not available, grounding must conform to the National Electric Code, article 250-95. The ground connection must be made to a proven earth ground, not to conduit or water pipes.

Do not connect ground to neutral (N-white wire) leg at J-box terminal strip.

Phase Adder

If three-phase service is unavailable for a 2 speed model and a Roto-Phase or other phase adder is used, connect artificial leg to L3 in input power junction box.

IMPORTANT: Do not use a phase adder on any variable-speed machine.

Control Function Test Procedure

In the machine, you will find the warranty registration card, the wiring diagram and other pertinent material. The warranty card should be filled out and returned to Alliance Laundry Systems. The other material should be removed and put in a safe place for future reference as needed.

The machine should be cleaned when the installation is completed, and a function test executed without a load in the machine as follows:

1.Check power supply for correct characteristics as to voltage, phase and cycles to be sure they are correct for the machine.

2.Open manual water shut-off valves to the machine.

3.Turn on electric power.

4.Select Cycle 01 by pressing “0” and “1” on the keyboard and press START.

5.To fast advance through the test cycle, press the ADVANCE key (drain steps must be allowed to complete).

6.Check the door interlock by opening the loading door (press and hold the door unlock button) and attempt to start the machine in the normal manner. The machine must not start while the door is open.

Close the door without fully locking it. Attempt to start the machine. The machine must not start without the door being fully closed and fully locked.

Close and lock the door and start the machine. Attempt to open the door while the machine is operating. The door must remain locked and can not be opened while the machine is operating.

7.Run a complete cycle and check operation of water inlet valves, drain and spin (extract) functions.

8.Rotation must be clockwise in spin (extract) step. If not, reverse line L1 and l2 at the J-box.

18

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F232158