Allied Air Enterprises 80G1UH, A80UH Service, Electrical Shock, Fire Or Explosion Hazard, Blower

Models: 80G1UH A80UH

1 39
Download 39 pages 24.29 Kb
Page 33
Image 33
Service

Service

ELECTRICAL SHOCK, FIRE,Blower WARNING

ELECTRICAL SHOCK, FIRE,

OR EXPLOSION HAZARD.

Failure to follow safety warnings exactly could result in dangerous operation, serious injury, death or property damage.

Improper servicing could result in dangerous operation, serious injury, death, or property damage. Before servicing, disconnect all electrical power to furnace.

When servicing controls, label all wires prior to disconnecting. Take care to reconnect wires correctly. Verify proper operation after servicing.

At the beginning of each heating season, a qualified technician should check the system as follows:

Blower

Check the blower wheel for debris and clean if necessary. The blower motors are prelubricated for extended bearing life. No further lubrication is needed.

Flue And ChimneyManual background WARNING

The blower access panel must be securely in place when the blower and burners are operating. Gas fumes, which could contain carbon monoxide, can be drawn into living space resulting in personal injury or death.

Filters

Filters are installed external to the unit. Filters should be inspected monthly. Clean or replace the filters when necessary to ensure that the furnace operates properly. Replacement filters must be rated for high velocity airflow. Table 1 lists recommended filter sizes.

Flue And Chimney

1.Check flue pipe, chimney and all connections for tightness and to make sure there is no blockage.

2.Check unit for proper draft.

Electrical

1.Check all wiring for loose connections.

2.Check for the correct voltage at the furnace (furnace operating). Correct voltage is 120VAC ± 10%.

3.Check amp draw on the blower motor with inner blower panel in place.

Unit Nameplate___________Actual_______________

506526-01

Issue 1031

Page 33 of 39

Page 33
Image 33
Allied Air Enterprises 80G1UH Service, Electrical Shock, Fire Or Explosion Hazard, Blower, Flue And Chimney, Filters