Horizontal Position

Horizontal Position

HORIZONTAL LEFT POSITION

Top Vent discharge

Disconnect pressure switch hose from barbed fitting on the pressure switch assembly. Remove pressure switch assembly (1 screw) and cut wire tie to free pressure switch wires. Reinstall pressure switch on the other side of orifice plate and reconnect pressure switch hose.

Resecure pressure seitch wires: Either pull excess wires through the blower compartment and secure using supplied wire tie, or coil excess wire and secure to the gas manifold.

Figure 19

HORIZONTAL LEFT POSITION

Side Vent Discharge

HORIZONTAL RIGHT POSITION

Top Vent Discharge

Remove make-up box assembly (2 screws) and cut wire tie to free make- up box wires. Reinstall make-up box on other side of cabinet.

Resecure make-up box wires: Either pull excess wires through the blower compartment and secure using supplied wire tie, or coil excess wire and secure to the gas manifold.

Figure 21

HORIZONTAL RIGHT POSITION

Side Vent Discharge

Disconnect pressure switch hose from barbed fitting on the pressure switch assembly. Remove pressure switch assembly (1 screw) and cut wire tie to free pressure switch wires. Reinstall pressure switch on the other side of orifice plate and reconnect pressure switch hose.

Resecure pressure seitch wires: Either pull excess wires through the blower compartment and secure using supplied wire tie, or coil excess wire and secure to the gas manifold.

Figure 20

Figure 22