Horizontal Position
HORIZONTAL LEFT POSITION
Top Vent discharge
•Disconnect pressure switch hose from barbed fitting on the pressure switch assembly. Remove pressure switch assembly (1 screw) and cut wire tie to free pressure switch wires. Reinstall pressure switch on the other side of orifice plate and reconnect pressure switch hose.
•Resecure pressure seitch wires: Either pull excess wires through the blower compartment and secure using supplied wire tie, or coil excess wire and secure to the gas manifold.
Figure 19
HORIZONTAL LEFT POSITION
Side Vent Discharge
HORIZONTAL RIGHT POSITION
Top Vent Discharge
•Remove
•Resecure
Figure 21
HORIZONTAL RIGHT POSITION
Side Vent Discharge
•Disconnect pressure switch hose from barbed fitting on the pressure switch assembly. Remove pressure switch assembly (1 screw) and cut wire tie to free pressure switch wires. Reinstall pressure switch on the other side of orifice plate and reconnect pressure switch hose.
•Resecure pressure seitch wires: Either pull excess wires through the blower compartment and secure using supplied wire tie, or coil excess wire and secure to the gas manifold.
Figure 20
Figure 22
Page 14 of 39 | Issue 1031 |