Allied Air Enterprises 92G1DF, A95DF, A93DF Burner Orifice Conversion Kits at Varying Altitudes

Models: A95DF 95G1DF A93DF 92G1DF

1 48
Download 48 pages 31.8 Kb
Page 37
Image 37

Burner Orifice Conversion Kits at Varying Altitudes

 

0 - 7,500 ft

 

7,501 - 10,000 ft

 

(0 - 2,286 m)

(2,286 - 3,038 m)

 

 

 

 

 

 

 

Natural

LP/Propane

High Altitude

High Altitude

Unit

Natural

LP/Propane

to

 

to

Size

 

Burner Orifice

Burner Orifice

LP/Propane

 

Natural

 

 

Kit

Kit

 

 

 

 

 

 

 

 

 

 

All

68W75*†

 

73W80*

51W01

68W70*†

 

 

 

 

 

 

*Conversion requires installation of a gas valve regulator spring which is provided with the gas conversion kit.

† LP kit includes low line pressure switch.

A93 and 92G1 Pressure Switches at Varying Altitudes

Unit

0 - 4,500 ft

4,501

- 7,500 ft

7,501 - 10,000 ft

Size

(0 - 1,373 m)

(1,373

- 2,286 m)

(2,286 - 3,038 m)

 

 

 

 

All

No Change

No Change

74W91

 

 

 

 

 

Pressure switch is factory set. No adjustment necessary.

All models use the factory installed pressure switch from 0 - 7,500 feet.

A95 and 95G1 Pressure Switches at Varying Altitudes

 

Unit

0 - 4,500 ft

4,501 - 7,500 ft

7,501 - 10,000 ft

 

Size

(0 - 1,373 m)

(1,373 - 2,286 m)

(2,286 - 3,038 m)

 

 

 

 

 

 

045

No Change

No Change

74W90

 

 

 

 

 

070

No Change

77W43

73W22

 

 

 

 

 

090

No Change

77W42

73W22

 

 

 

 

 

110

No Change

77W43

73W22

 

 

 

 

 

135

No Change

77W42

73W22

 

 

 

 

 

Pressure switch is factory set. No adjustment necessary.

All models use the factory installed pressure switch from 0 - 4,500 feet.

TABLE 14

506725-01

Issue 1109

Page 37 of 48

Page 37
Image 37
Allied Air Enterprises 92G1DF, A95DF, A93DF, 95G1DF dimensions Burner Orifice Conversion Kits at Varying Altitudes