Allied Air Enterprises Upflow specifications Adjusting Airflow

Models: Downflow or Horizontal 2 Stage Heat Variable Speed Gas Fired Non-Condensing Warm Air Furnace Upflow

1 28
Download 28 pages 32.15 Kb
Page 4
Image 4
Adjusting Airflow

BLOWER MOTOR SPECIFICATIONS AND AIRFLOW ADJUSTING DATA

Adjusting Airflow

 

 

 

 

HEAT SETTINGS

 

 

COOL SETTINGS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODEL

MOTOR

BLOWER

HEATING CFM @ .50 STATIC

 

COOL CFM @ .50 STATIC

 

HP

WHEEL

 

 

 

 

 

 

 

 

 

 

 

SETTING

SETTING

SETTING

SETTING

COOLING

SETTING

SETTING

 

SETTING

SETTING

 

 

 

 

 

 

 

"A"

"B"

"C"

"D"

ADJUSTMENT

"A"

"B"

 

"C"

"D"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NORM

1200

1000

 

800

600

AV050B3

1/2

10 X 6

525

425

325

625

( + )

1380

1150

 

920

690

 

 

 

 

 

 

 

( - )

1020

850

 

680

510

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NORM

1200

1000

 

800

600

AV075B3

1/2

10 X 6

740

640

540

840

( + )

1380

1150

 

920

690

 

 

 

 

 

 

 

( - )

1020

850

 

680

510

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NORM

1600

1400

 

1200

1000

AV100B4

3/4

12 X 9

1250

1150

1050

1350

( + )

1800

1610

 

1380

1150

 

 

 

 

 

 

 

( - )

1360

1190

 

1020

850

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NORM

2000

1800

 

1600

1400

AV125B5

3/4

12 X 12

1650

1550

1450

1750

( + )

2200

2070

 

1840

1610

 

 

 

 

 

 

 

( - )

1700

1530

 

1360

1190

 

 

 

 

 

 

 

 

 

 

 

 

 

THE UNIT, AS SHIPPED, IS FACTORY SET AT SETTING "A" TO RUN AT THE MIDDLE OF THE HEATING RISE RANGE SHOWN ON THE UNIT RATING LABEL.

When operating the furnace in the heating mode, the static pressure and the temperature rise (supply air temperature minus return air temperature) must be within those limits specified on the rating label. Failure to follow this warning could lead to severe furnace damage.

Turn OFF all gas and electrical power to furnace before performing any maintenance or service on unit. (Unless specific test requires gas and electrical supplies.) Failure to take this precaution may result in personal injury due to electrical shock or uncontrolled gas leakage.