Configuring System Time

Configuring SNTP

Configuring SNTP

The device supports the Simple Network Time Protocol (SNTP). SNTP assures accurate network device clock time synchronization up to the millisecond. Time synchronization is performed by a network SNTP server. The device operates only as an SNTP client, and cannot provide time services to other systems. The device can poll the following server types for the server time:

Unicast

Anycast

Broadcast

Time sources are established by stratums. Stratums define the accuracy of the reference clock. The higher the stratum (where zero is the highest), the more accurate the clock. The device receives time from stratum 1 and above. The following is an example of stratums:

Stratum 0 — A real time clock (such as a GPS system) is used as the time source.

Stratum 1 — A server that is directly linked to a Stratum 0 time source is used. Stratum 1 time servers provide primary network time standards.

Stratum 2 — The time source is distanced from the Stratum 1 server over a network path. For example, a Stratum 2 server receives the time over a network link, via NTP, from a Stratum 1 server.

Polling for Unicast Time Information

Polling for Unicast information is used for polling a server for which the IP address is known. T1 - T4 are used to determine the server time. This is the preferred method for synchronizing device time.

Polling for Anycast Time Information

Polling for Anycast information is used when the SNTP server IP address is unknown. The first Anycast server to return a response is used to set the time value. Time levels T3 and T4 are used to determine the server time. Using Anycast time information for synchronizing device time is preferred to using Broadcast time information.

Broadcast Time Information

Broadcast information is used when the server IP address is unknown. When a broadcast message is sent from an SNTP server, the SNTP client listens for the response. The SNTP client neither sends time information requests nor receives responses from the Broadcast server.

Message Digest 5 (MD5) Authentication safeguards device synchronization paths to SNTP servers. MD5 is an algorithm that produces a 128-bit hash. MD5 is a variation of MD4, and increases MD4 security. MD5 verifies the integrity of the communication, authenticates the origin of the communication.

To define SNTP global parameters:

1.Click System > System Time. The System Time Page opens.

The SNTP Settings section of the System Time Page contains the following fields:

Status — Indicates if SNTP is enabled on the device. The possible field values are:

Disabled — Indicates that SNTP is disabled.

Enabled — Indicates that SNTP is enabled.

Server IP Address — Displays a user-defined SNTP server IP address.

Poll Interval — Defines the interval (in seconds) at which the SNTP server is polled for Unicast information. The Poll Interval default is 1024 seconds.

2.Select the SNTP Status.

Page 23

Page 24
Image 24
Allied Telesis AT-8000S manual Configuring Sntp, Polling for Unicast Time Information, Polling for Anycast Time Information

AT-8000S specifications

The Allied Telesis AT-8000S series switches are a range of advanced Layer 2 Ethernet switches designed for efficient networking in various environments. Engineered with performance, reliability, and cost-effectiveness in mind, these switches are ideal for businesses seeking to enhance their network infrastructure.

One of the main features of the AT-8000S series is its high-speed data forwarding capabilities. With support for 10/100/1000 Mbps Ethernet ports, these switches provide fast and reliable connections, enabling seamless data transfer and enhanced communication between devices. The non-blocking switching architecture ensures that full bandwidth is available at all times, maximizing throughput and reducing latency in network traffic.

The AT-8000S series incorporates advanced Layer 2 switching technologies, such as VLAN support, allowing users to segment network traffic for improved performance and security. Virtual Local Area Networks (VLANs) help isolate sensitive data and reduce unnecessary broadcast traffic, enhancing the overall performance of the network.

Quality of Service (QoS) is another significant feature integrated into these switches, prioritizing different classes of network traffic. This functionality ensures that critical applications receive the necessary bandwidth and minimal latency, which is imperative for voice over IP, video conferencing, and other latency-sensitive applications.

In terms of network management, the AT-8000S series provides a variety of options, including an intuitive web-based interface, SNMP support, and the ability to manage switch configurations through console access. This flexibility allows network administrators to monitor performance and manage configurations easily.

The switches are built for durability, featuring a robust design suitable for deployment in various environments, including temperature-sensitive areas. Power over Ethernet (PoE) capability is also available in certain models, allowing network devices like IP cameras and wireless access points to receive power through the same cable as data, simplifying installation and reducing clutter.

Allied Telesis emphasizes security within the AT-8000S series, with features such as port security, DHCP snooping, and IEEE 802.1X authentication to safeguard against unauthorized access and potential threats.

Overall, the Allied Telesis AT-8000S series provides a comprehensive networking solution tailored for modern business needs, combining performance, flexibility, and security to support a growing array of applications and devices within the network.