Viewing Statistics
Managing RMON Statistics
Page 165
Absolute — Compares the values directly with the thresholds at the end of the sampling interval.
Rising Threshold — Displays the rising counter value that triggers the rising threshold alarm. The rising
threshold is presented on top of the graph bars. Each monitored variable is designated a color.
Rising Event — Displays the mechanism in which the alarms are reported. The possible field values are:
LOG — Indicates there is not a saving mechanism for either the device or in the management system. If
the device is not reset, the entry remains in the Log Table.
TRAP — Indicates that an SNMP trap is generated, and sent via the Trap mechanism. The Trap can also
be saved using the Trap mechanism.
Both — Indicates that both the Log and Trap mechanism are used to report alarms.
Falling Threshold — Displays the falling counter value that triggers the falling threshold alarm. The falling
threshold is graphically presented on top of the graph bars. Each monitored variable is designated a color.
Falling Event — Displays the mechanism in which the alarms are reported.
Startup Alarm — Displays the trigger that activates the alarm generation. Rising is defined by crossing the
threshold from a low-value threshold to a higher-value threshold.
Interval (sec) — Defines the alarm interval time in seconds.
Owner — Displays the device or user that defined the alarm.
2. Click Create. The Add Alarm Page opens:
Figure 109:Add Alarm Page
3. Define the Interface, Counter Name, Sample Type, Rising Threshold, Rising Event, Falling Threshold, Falling
Event, Startup Alarm, Interval, and Owner fields.
4. Click Apply. The RMON alarm is added, and the device is updated.
To modify RMON alarms:
1. Click Statistics > Alarm. The RMON Alarm Page opens.