AT-9000 Gigabit Ethernet Switch Installation Guide

Console Port

The Console port is used to configure the features and parameter settings of the switch. This type of management uses serial RS-232 and is commonly referred to as local or out-of-band management because it is not conducted over your network. To perform local management, you must be at the location of the switch and use the management cable included with the switch.

To establish a local management session with the switch, connect a terminal or a personal computer with a terminal emulation program to the Console port, which has an RJ-45 style (8P8C) connector, using the provided management cable. The cable has RJ-45 RJ-style (8P8C) and DB-9 (D-sub 9-pin) connectors.

The Console port is set to the following specifications:

Default baud rate: 9600 bps (range is 9600 to 115200 bps)

Data bits: 8

Parity: None

Stop bits: 1

Flow control: None

Note

These settings are for a DEC VT100 or ANSI terminal, or an equivalent terminal emulation program.

36

Page 36
Image 36
Allied Telesis AT-9000/12POE, AT-9000/28POE manual Console Port