Installation and Safety Guide

Table 1: System LEDs (Continued)

 

 

 

LED

State

Description

 

 

 

PSU 2

Green

PSU 2 is installed and supplying power to the switch.

 

 

The voltage output is within specification.

 

 

 

 

Red

PSU 2 is installed in the switch and has exceeded its

 

 

recommended temperature threshold of 75º C

 

 

(167º F), or the fan has failed.

 

 

A FOM is installed in the switch and has failed.

 

 

The bay is empty.

 

 

 

 

Off

A FOM is installed and operating at an acceptable

 

 

speed.

 

 

 

Fault

Red

The switch or management software is

 

 

malfunctioning.

 

 

 

 

1 Flash

One or more heatsink fans has failed or is operating

 

 

below the recommended speed.

 

 

 

 

6 Flashes

The switch’s temperature has exceeded the

 

 

recommended threshold. After flashing six times,

 

 

the LED stops briefly, then repeats the sequence.

 

 

 

 

Slow

The SDRAM (DIMM) has not been detected.

 

flashing at

 

 

startup

 

 

 

 

 

Rapid

The SDRAM (DIMM) is not compatible with the

 

flashing at

switch.

 

startup

 

 

 

 

CF

Green

The CompactFlash memory card is active and

 

flashing

should not be ejected. The card can be safely ejected

 

 

when the LED remains off.

 

 

 

SD

Off

Secure Digital memory card. Not supported by 3.0.1

 

 

software.

 

 

 

13