Altinex MT110-103 manual 17. IO, 18. IO, 19. …P - PATH, Sw - Switch, Osi, Oso, Vlo, Multitasker

Models: MT110-103

1 26
Download 26 pages 31.17 Kb
Page 15
Image 15
17.[IO]

MULTITASKER

17.[IO]

This command connects a single input to a single output in the current matrix configuration.

Command Format: [ImOxCn]

m= Input (m= # from 1 to 8) x = Output (x = # from 1 to 8)

Cn = Card ID (n = slot # from 1 to max slots) Example:

Connect Input 1 to Output 1 for the MT110-103in slot 4. Send the command [I1O1C4] and Input 1 will be connected to Output 1.

18.[IO*]

This command connects a single input to all the outputs in the current matrix configuration.

Command Format: [ImO*Cn]

m = Input (m = # from 1 to 8)

Cn = Card ID (n = slot # from 1 to max slots)

Example:

Connect Input 1 to all outputs for the MT110-103in slot 4. Send the command [I1O*C4] and Input 1 will be connected to all outputs.

19.[…P] – PATH

This command will set the path for the output, but it is not active until the switch command, [SW], is executed. Commands ending in ‘P’ are not executed immediately. The path for outputs on multiple cards or the same card can be preloaded. See the examples for the [ON] and [OFF] commands.

20.[SW] – SWITCH

This command immediately connects inputs and outputs previously set with the PATH command. The command switches all paths set on this card and all other cards in the enclosure. See the examples for the [ON] and [OFF] commands.

21.[OSI]

This command sets the input offset value that is applied to all inputs. The default is zero, or Input 1 equals Input 1.

Command Format: [OSImCi]

m = Offset (m = # from 0 to 128)

Ci = Card ID (i = # from 1 to max slots)

Example:

[OSI16C4] sets the input offset to 16 for C4. The inputs on C4 will now be their physical number plus the offset value. In this case, Input 1 would now be Input 17.

22.[OSO]

This command sets the output offset value that is applied to all outputs. The default is zero, or Output 1 equals Output 1.

Command Format: [OSOmCi]

m = Offset (m = # from 0 to 128)

Ci = Card ID (i = # from 1 to max slots)

Example:

[OSO16C4] sets the output offset to 16 for the C4. The outputs on C4 will now be addressed by the value of their physical number plus the offset value. In this case, Output 1 would now be Output 17.

23.[VLO]

This command sets the absolute volume level for a given output.

Command Format: [VLOmAvCn]

m = Output (m = # from 1 to 8)

v= Volume Level (v = # from 1 to 32) Cn = Card ID (n = # from 1 to max slots) Example:

There is an MT110-103card in slot 4. Set the output volume of Output 2 to 16 by sending the command [VLO2A16C4].

400-0197-006