Altinex MT110-103 manual STA1, STA0, 13. …F - FEEDBACK, Multitasker

Models: MT110-103

1 26
Download 26 pages 31.17 Kb
Page 12
Image 12
11.[STA1]

MULTITASKER

All status feedback is enclosed in brackets, “[ ]“. Each data field within the status is enclosed in parentheses. The first two characters identify the status type. The last three characters are the card’s ID.

MT110-103

= Card model number

VR690-0152-011

= Firmware version

ON1111111

= Output ON/OFF status

MA01010101...01

= Matrix connections

MX8x8C04

= Matrix configuration

VO323232...32

= Output volume settings

MU0C04

= Mute status

The ON/OFF status line is read from left to right as Outputs 1-8. A "1" indicates the output is on and a "0" indicates the output is off.

The matrix connections are also read left to right representing Outputs 1-8 and the input to which each is connected. The first two digits show the input number to which Output 1 is connected. The third and forth digits are for Output 2 and so on.

The matrix configuration is the size of the matrix. In this case, the matrix has 8 inputs and 8 outputs.

The output volume settings are read left to right representing Outputs 1-8 and the volume to which each is set. The first two digits show the volume level for Output 1. The third and forth digits are for Output 2 and so on.

11.[STA1]

This command enables automatic feedback from the front panel. The command affects any card with auto-feedback capability, not just the MT110-103. The default at power on or reset is STA0, off. For more details, see the [?Cn] command definition.

Command Format: [STA1]

Feedback Prefix Definitions:

MT Card model number

VR Firmware version

ON Output on/off status

MA Matrix connections

MX Matrix configuration

VO Output volume

MUMute

Example:

Command = [I1O*C4]

Feedback = (MA0101010101010101C04)

MA = Matrix connections 0101...01 = Input 1 to all outputs

C04 = Card ID/slot number

12.[STA0]

This command disables automatic feedback from the card and front panel. The command affects any card with auto-feedback capability, not just the MT110-103card. The default at power on or reset is STA0, OFF.

Command Format: [STA0]

13.[…F] – FEEDBACK

After processing a command, an “OK” or “[ERR001]” will be returned as feedback if “F” is included at the end of a command string.

400-0197-006

11

Page 12
Image 12
Altinex MT110-103 manual STA1, STA0, 13. …F - FEEDBACK, Multitasker