7.0 Troubleshooting and correction

US

You have chosen the best quality and therefore deserve the best service. To avoid unnecessary disap- pointments, you should check the following before contacting the nearest ALTO service organisation:

Fault

 

Cause

Correction

Machine will not start

A fuse has blown

Change the fuse

 

 

Power/plug not connected

Connect power/plug

 

 

Thermal switch in motor

Let the motor cool. Start the machine and

 

 

activated

check that the working pressure is

 

 

 

not too high and that the mains voltage

 

 

 

corresponds to the specifications.

 

KSA-2

Thermal switch in water tank

Let the water cool and check that the inlet

 

 

 

water temp does not exceed 160°F.

Machine stops shortly

Wrong supply voltage

Check that the supply voltage corresponds

after the start

 

 

to the specifications on the model tag

 

 

 

(see section 1.1).

 

 

Air in the system

Vent the system (see section 3.4).

Fuses blow

 

Supply is inadequate

Correct the installation so it corresponds to

 

 

for the ampere

the ampere consumption of the machine

 

 

consumption of the machine

at a minimum. Change fuse.

Working pressure

KSA-1

Nozzle partly clogged

Clear nozzle (see section 6.4)

too high

 

 

 

Working pressure too low

High pressure cock by outlet

Close all high pressure cocks not in use.

 

 

point not completely closed

 

 

KSA-1

Water regulation valve not

Completely open the water regulation valve.

 

 

set at max pressure

Turn in the direction of the indicator.

 

KSA-2

Wrong MULTIPRESSURE

Check whether the total water volume of the

 

 

spray lance

spray lances in use exceeds the capacity of

 

 

 

the system. If necessary, change to other

Pressure fluctuating

 

 

spray lances.

 

High pressure hoses too

Detach high pressure extension hoses and

 

 

long

(machine vibrates) retry. Extension hose

 

 

 

max. 160 ft. Avoid long extension hoses

 

 

 

with many couplings.

 

 

Air in the system

Vent the system (see section 3.4)

 

 

Water inlet screen clogged

Clean the screen (see section 6.3)

No working pressure

Nozzle clogged

Clear the nozzle (see sec. 6.4)

 

 

No inlet water

Check that the shut-off cock of the water

 

 

 

supply is open. Check that the water supply

 

 

 

is adequate (see section 1.2).

 

 

High pressure cock of

Close all high pressure cocks not in use.

 

 

outlet point is open

 

Water volume too

KSA-1

Water regulation valve not

Open water regulation valve completely.

low

 

set properly

Turn completely open in the direction of the

 

 

 

indicator.

 

KSA-2

Nozzle partly blocked

Clear the nozzle (see section 6.4).

Should other malfunctions occur than those mentioned above, please contact your authorized ALTO servicing distributor.