Alto-Shaam 52C3KSA -1, 52C3KSA -2 manual Installation US 3.4 Venting, Turn to position „Start“

Models: 52C3KSA -1 52C3KSA -2

1 24
Download 24 pages 1.39 Kb
Page 9
Image 9
Installation US

Installation US

3.4 Venting

KSA-1

O

1

Start

Turn to position „Start“

Activate spray handle/open outlet point

In the case of newly installed systems, or if the pipeline and the pump have been drained in any other way, the system should be vented by starting the pump and then let the water run freely at each outlet point of the pipeline in turn.

When connecting the high pressure hose directly to the machine, the system should be vented by starting the pump and activating the trigger of the spray handle without the spray lance attached.

Let the water run until all air has escaped from the pump (regular water flow).

KSA-2

In the case of newly installed systems, or if the pipeline and the pump have been drained in any other way, the system should be vented as follows:

O1. Start pump no. 1 and let the water run from an outlet point of the pipe-line.

When connecting a high pressure hose directly to the machine, activate

 

 

the trigger of the spray handle without the spray lance attached.

1+2

1

Let the water run until all air has escaped from the pump (regular water

flow).

2

O2. Stop pump no. 1. Then start pump no. 2 and let the water run from an outlet point of the pipeline. When connecting a high pressure hose directly

 

 

to the machine, activate the trigger of the spray handle without the spray

1+2

1

lance attached. Let the water run until all air has escaped from the pump

(regular water flow).

3. Vent the pipeline by starting a pump and letting the water run from each

2outlet point (begin with the outlet farthest from the machine) until all air has escaped from the system.

9

Page 9
Image 9
Alto-Shaam 52C3KSA -1, 52C3KSA -2 manual Installation US 3.4 Venting, Turn to position „Start“