Alto-Shaam ASC-4G Ga s Supply & Installation, GAS ConnECtIon foR ovEnS on CAStERS, lEAk tEStInG

Models: ASC-4G

1 30
Download 30 pages 2.14 Kb
Page 9
Image 9
Ga s Supply & Installation

Ga s Supply & Installation

GAS ConnECtIon

foR ovEnS on CAStERS

The oven must be supplied with a flexible connector that complies with The Standard for Connectors for Movable Gas Appliances, ANSI Z21.69, CGA 6.16 and addenda Z21.69a (latest editions). A quick disconnect device must be installed to comply with The Standard for Quick Disconnect Devices for Use with Gas Fuel, ANSI Z21.41 and CAN1-6.9 (latest editions). A flexible connector is not supplied by the factory.

lEAk tEStInG

Use a soap and water solution on all gas supply line connections.

GAS ConnECtIon DAnGER

nEvER uSE An opEn flAME to lEAk tESt.

Adequate means must be provided to limit the movement of the appliance. Limitation of movement must be made without depending on the connector, the quick disconnect device, or the associated piping designed to limit oven movement. Mounting holes for a restraining device are located on the lower back flange of the oven chassis.

CORRECT

RESTRAINT

Shut the gas supply OFF if it becomes necessary to disconnect the restraint. Reconnect the restraint immediately following the return of the oven to its original position. turn the gas supply ON after the restraint has been reconnected.