6 inch ducting pieces

6 inch to 3¼ x 10 inch transition = 5 equivalent feet

6 inch to 3¼ x 10 inch transition = 1 equivalent foot

6 inch 90 degree elbow =

5 equivalent feet

6 inch 45 degree elbow = 2½ equivalent feet

6 inch wall cap (Unrestricted) = 0 equivalent feet

Electrical Installation Requirements

Installation of this product must conform with local codes or in the absences of local codes with the current National Electric Code ANSI NFPA 70 or Canadian Electrical Codes.

Cooktop requires a 3 wire 240 volt, 60 hertz, AC circuit protected by a separate 30 amp circuit breaker or time delay fuse. Ground cooktop using #10 gauge ground wire attached to burner box.

Junction Box Location

Power supply enters cooktop in right, rear corner. Junction box must be located within 30 inches of power supply entry point. Locate junction box within shaded area.

A

B

D

C

A—6¾ inches

B—Within 30 inches of power supply entry point C—24 inches

D—Center line