2.Electrical Service Specifications

ADG-120ES Reversing, 3ø (GAS) ADS-120ES Reversing, 3ø (STEAM )

ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)

IMPORTANT: 208 VAC and 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

NOTES: A. Fuse ratings are dual-element, time-delay, current limiting, class RK1 or RK5 ONLY.

B.Circuit breakers are thermal magnetic (industrial) type ONLY . For others, calculate/verify correct breaker size according to appliance amp draw rating and type of breaker used.

C.Circuit breakers for 3Ø dryers must be 3-pole type.

SERVICE

 

WIRE

APPROX.

MINIMUM

FUSING

CIRCUIT

PHASE

Dual Element

AMP DRAW

BREAKER

VOLTAGE

SERVICE

WIRE SIZE*

Time Delay

 

 

 

 

 

 

 

 

60 Hz

50 Hz

 

60 Hz

50 Hz

60 Hz

50 Hz

120

3/4

14.6

---

14

20

---

25

---

 

 

 

 

 

 

 

 

 

 

240

3

13.3

14

14

20

20

25

25

 

 

 

 

 

 

 

 

 

 

380

3/4

8

7.6

14

12

10

15

15

 

 

 

 

 

 

 

 

 

 

416

3/4

---

7.4

14

---

10

---

15

460

3/4

7.1

---

14

---

---

15

---

480

3/4

7.1

7

14

10

---

15

---

 

 

 

 

 

 

 

 

 

 

575

3

6.3

---

14

10

10

15

15

 

 

 

 

 

 

 

 

 

 

*AWG Stranded Type Wire ... for individual lengths less than 100 feet. (Motor lead type wire is recommended)

IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is affixed to the back of the dryer, at the upper right hand corner. In the case of 208 VAC or 240 VAC, the supply voltage must match the electric service specifications of the data label exactly.

WARNING: 208 VAC and 240 Volts ARE NOT THE SAME. Any damage done to dryer components due to improper voltage connections will automatically VOID THE WARRANTY.

NOTE: ADC reserves the right to make changes in specifications at any time, without notice or obligation.

22

Page 26
Image 26
American Dryer AD-120ES manual ADG-120ES Reversing, 3ø GAS ADS-120ES Reversing, 3ø Steam