19
MLS-200 (Ste a m)15 Hp Blower/3 Hp Driv e M otor

E

LECTRIC

S

ERIVICE

S

PECIFICATIONS

(

PER DRYER

)

IMPORTANT:
208 VAC and 230 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTES: A. Fuse ratings are du al e leme nt- time d el ay -cu rre nt lim iting , clas s R K 1 o r R K 5 ON LY.
B. Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify corre ct bre ake r size
according to appliance amp draw rating and type of breaker used.
C. Circuit breakers for 3 dryers must be 3-pole type.
SERVICE
VOLTAGE PHASE WIRE
SERVICE
APPROX.
AMP DRAW MINIMUM
WIRE
SIZE*
FUSING
Dual Element
Time Dela y
CIRCUIT
BREAKER
60 Hz 50 Hz
208 3Ø3/4 54 --- 4 80 90
230 3Ø3 48 --- 4 80 90
380 3Ø3/4 --- 29 10 40 60
416 3Ø3/4 --- 27 10 40 60
460 3Ø3/4 25 --- 10 40 60
* AWG Stranded Type Wire...for individual lengths less than 100 feet (30.48 meters).
WARNING: 208 VAC and 230 VAC ARE NOT THE SAME. Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
IMPORTANT: The dryer must be connected to the electrical supply shown on the data label that
is affixed to the back of the dryer, at the upper right hand corner. In case of 208 VAC
or 230 VAC, the supply voltage must match the electric service specifications of the
data label exactly.
NOTE: ADC RESERVES THE RIGHT TO MAKE CHANGES IN SPECIFICATIONS AT ANY
TIME, WITHOUT NOTICE or OBLIGATION.