a.Lint drawer switch is out of proper adjustment.
b.Loose connection in the lint drawer switch circuit.
J.Microprocessor controller (computer) L.E.D. (light emitting diode) display reads "dSFL" continuously and the buzzer (tone) sounds every
1.Fault in microprocessor heat sensing circuit ...
a.Failed microprocessor temperature sensor.
b.Blown "dSFL"
c.Failed microprocessor controller (computer).
d.Broken wire or connection somewhere between the microprocessor controller (computer) and the microprocessor temperature sensor.
K.Microprocessor controller (computer) L.E.D. (light emitting diode) display reads "door" and the microprocessor controller "door" L.E.D. indicator is off...
1.Fault (open circuit) in main door/lint drawer switch circuit ...
a.Lint drawer is not closed ALL the way.
b.Lint drawer switch is out of proper adjustment.
c.Failed lint drawer switch.
d.One (1) of the main door switches has failed.
e.One (1) of the main door switch contact magnets is either missing or broken.
f.Failed door switch relay.
g.Broken wire/connection in main door or lint drawer switch circuit.
2.Failed 24 VAC step down transformer.
3.Drive and/or blower (impellor/fan) motor thermal overload reset had tripped.
45