8.Each dryer should be operated through one (1) complete cycle to assure that no further adjustments are necessary and that ALL components are functioning properly.
9.Microprocessor (computer) programs/selections...
a.Each microprocessor controller (computer) has been preprogrammed by the factory with the most commonly used parameter selections. If computer program changes are required, refer to the Computer Programming Manual which was shipped with the dryer.
K. SHUT DOWN INSTRUCTIONS
In the case where the dryer is to be shut down (taken out of service) for a period of time, the following must be performed:
1.Discontinue power to the dryer either at the external disconnect switch or the circuit breaker.
2.Disconnect the heat supply:
a.GAS MODELS ... discontinue the gas supply.
1)SHUT OFF external gas supply
2)SHUT OFF internal gas supply
b.STEAM MODELS ... discontinue steam supply.
1)SHUT OFF external (location furnished)
2)SHUT OFF internal steam valves in the supply lines and the return lines.
32