SECTION X
MANUAL RESET HI-LIMIT INSTRUCTIONS
I M P O R T A N T
MANUAL RESET HI-LIMIT INSTRUCTIONS
FOR GAS MODELS WITH PHASE 5
This dryer was manufactured with a manual reset burner hi-limit and tumbler/lint chamber hi-limit thermostat which is monitored by the Phase 5 computer. If either manual reset thermostat is open prior to start of the drying cycle, the dryer will start momentarily and then shut down.
The open manual reset hi-limit thermostat must be reset “manually” prior to the start of the next cycle.
This hi-temperature condition may be caused due to a restricted exhaust, poor airflow or improper burner oven operation.
The location of the manual reset hi-limit is on the right side of the burner box and the tumbler hi-limit is located in the lint chamber area.
WARNING: Discontinue power to dryer before attempting to reset hi-limit.
IMPORTANT
This dryer is equipped with a burner hi-limit and tumbler/lint chamber hi-limit thermostat which must be reset manually.
WARNING: Discontinue power to dryer before attempting to reset hi-limit.
ADC P/N: 114093