I M P O R T A N T

MANUAL RESET HI-LIMIT INSTRUCTIONS

FOR TIMER OR PHASE 5 WITHOUT HEAT FAULT

(ELECTRIC OR STEAM MODELS ONLY)

This dryer was manufactured with a basket (tumbler)/lint chamber* manual reset hi-limit thermostat. If the manual reset thermostat is open prior to the start of the drying cycle, or during the cycle, the dryer will not recognize the open state of the hi-limit thermostat and will start or continue through the drying cycle with no heat. The applicable manual reset hi-limit must be reset manually.

This hi-temperature condition may be caused due to a restricted exhaust, poor airflow, or improper heating unit operation.

The location of the manual reset hi-limit switch is in the lint chamber area.

WARNING: Discontinue electrical power to the dryer before attempting to reset hi-limit.

* Models manufactured as of November 7, 2001 have an automatic reset lint chamber hi-limit.

IMPORTANT

This dryer is equipped with a lint chamber* hi-limit thermostat which must be reset manually.

WARNING: Discontinue power to dryer before attempting to reset hi-limit.

ADC P/N:114501

62

Page 66
Image 66
American Dryer Corp AD-115ES II installation manual ADC P/N114501