63
-If yes, adjust the “Time Adjust” until the L.E.D. (light emitting diode) is on during rotation 15 to 20
seconds after the tumbler stops
-If “NO,” check:
-Inductive proximity sensor is located in the same area as the tumbler junction box
-Inductive proximity mechanical adjustment
-The target that is attached to the outside of the basket
-Stop motion detector module
-Circuit wiring; refer to ADS-464 Main Panel Wiring Diagram, ADS-464 Tumbler Junction Box
Wiring Diagram
1b) If the L.E.D. (light emitting diode) is constantly “ON”
-If “YES,” the stop motion detector is defective
-If “NO,” check:
-Inductive proximity sensor for damage. The proximity sensor is located in the same area as the
tumbler junction box.
-Inductive proximity mechanical adjustment
-Tumbler target...this target is attached to the outside of the basket
-Stop motion detector module in the tumbler section on the left front side
-Circuit Wiring; refer to ADS-464 Main Panel Wiring Diagram
-ADS-464 Tumbler Junction Box Wiring Diagram