If RTD (Resistive Temperature Device) probe is defective, replace the probe.

NOTE: If ALL systems check out fine, call the ADC Service Department at (508) 678-9000.

2.No Control Power (“BLUE” Light Off)

a.PROBABLE CAUSES;

1a) Line voltage from main fused disconnected.

2a) Main disconnect on the ADS-464 is turned off.

3a) OL11 (overload #11) tripped.

4a) Fuse #1 is blown.

b.POSSIBLE SOLUTIONS;

1b) Verify main line voltage to ADS-464

If line voltage is present go to paragraph #2b below

If line voltage is not present check fused disconnect and re-test

2b) Attempt to turn the ADS-464 main power handle to the “ON” position

If the switch does not engage, verify that sprinkler power is “ON” (“RED” light on main door)

If “NO,” refer to paragraph #1b above

3)Open main enclosure and verify that OL11 has not tripped

If “YES,” check circuit, restart and test

If “NO.” go to section #3 on page 47

Verify that fuse #1 has not blown, check that the “RED” L.E.D. indicator is off.

If “ON.” (fuse block L.E.D. “ON”), check circuit, replace fuse and test.

46

Page 50
Image 50
American Dryer Corp ADS-464 manual No Control Power Blue Light Off