A. POWER MALFUNCTIONS

1.Main Disconnect Will Not Turn On

a.PROBABLE CAUSES;

1a) Sprinkler isolated power source “OFF” or disabled.

2a) OL12 tripped or sprinkler circuit defective.

3a) Sprinkler activated.

4a) Sprinkler will not reset.

b.POSSIBLE SOLUTIONS;

1b) Verify “RED” “Sprinkler Power” on main panel to be illuminated.

If “ON” go to paragraph #3b below

If “NOT ON” verify isolated sprinkler power source to the dryer Check sprinkler supply voltage at TB1 Pin #4 and Pin #5

If “OK” go to paragraph #2b below

If none, check incoming line voltage

If none, check fuse disconnect switch

2b) Check if OL12 has tripped.

If “OK” go to paragraph #3b below

If tripped, check sprinkler circuit, then reset and test.

3b) Check if sprinkler is activated...is the “SPRINKLER RESET” button “lit”?

If “YES,” press “SPRINKLER RESET” Does the sprinkler reset?

If “YES,” attempt to turn “ON” the main disconnect again

If “NO” go to paragraph #4b below and on page 46

4b) Sprinkler will not reset, verify that the sprinkler hi-limit has not tripped. (“GREEN” light is off.)

If it has not tripped, check setting to be 550º F (273º C) and verify that the sprinkler RTD (Resistive Temperature Device) is connected and has 100 ohms (100 Ω) at 32º F (0º C)/109 ohms (109 Ω) at 75º F (24º C)

45