5.Remove the screws securing the burner tube rest to the oven and remove this rest.

6.Remove screws securing the flame probe, and HSI Ignitor burner box cover plate to the oven.

7.Remove burner tubes by sliding them out.

8.Replace by reversing procedure.

WARNING: Test ALL connections for leaks by brushing on a soapy water solution.

WARNING: NEVER TEST FOR LEAKS WITH A FLAME!!!

To Replace HSI (Hot Surface Ignition) Module

1. Discontinue electrical power to the dryer.

2. Remove the wires connected to the terminal strip at the bottom of the module.

3. Remove the two (2) pal nuts securing the module to the mounting bracket.

4. Replace module by reversing procedure.

5. Reestablish electrical power to the dryer.

C. THERMOSTATS

To Replace Burner Hi-Limit Thermostat (Gas Models Only)

This thermostat is an important safety device serving as an added protection against failure of the airflow (sail switch) to open in the event of motor failure or reduced airflow condition.

IMPORTANT: UNDER NO CIRCUMSTANCES should heat circuit safety devices ever be disabled.

1. Discontinue electrical power to the dryer.

2. Disconnect wires from hi-limit thermostat.

3. Remove screw, washer, and nuts securing thermostat to the bracket. Remove thermostat.

4. Reversing procedure for installing new thermostat.

5. Reestablish electrical power to the dryer.

21

Page 25
Image 25
American Dryer Corp ML-145, ML-170 service manual To Replace HSI Hot Surface Ignition Module, Thermostats