38
I. Display is reading “Burner Control Failure.”
1. Faulty flame probe.
2. Faulty HSI (Hot Surface Ignition) module.
3. Faulty wiring connection between HSI module and gas valve or between gas valve and Phase 6 computer.
4. Faulty computer.
J. Display is reading “Burner Flame Failure.”
1. Clogged lint screen.
2. Clogged exhaust.
3. Faulty HSI module.
4. Faulty gas valve.
5. Dirty burner tubes.
K. Display is reading “Main Door.”
1. Faulty main door switch.
2. Faulty wiring connection between main door switch and Phase 6 computer.
3. Faulty computer.
L. Display is reading “Lint Door.”
1. Faulty lint door switch.
2. Faulty wiring connection between lint drawer switch and Phase 6 computer.
3. Faulty computer.
M.Display is reading “Temp Sensor Fail Check Temp Sensor Fuse.”
1. Blown 1/8 amp fuse on Phase 6 computer.
2. Faulty temperature sensor.
3. Faulty wiring connection between temp sensor and Phase 6 computer.
4. Faulty computer.