Refer to the system ladder diagram for “HEAT” signal information. There are several safety devices that must be satisfied prior to ignition. Any one of these safety devices can cause NO IGNITION, therefore a “BURNER FAULT”...i.e., FRONT AIRFLOW SWITCH
REAR AIRFLOW SWITCH
EXHAUST MANUAL RESET
ONE BURNER WILL NOT IGNITE AT THE BEGINNING OF A CYCLE
This condition can be caused by the following:
DEFECTIVE DSI (Direct Spark Ignition) MODULE
DEFECTIVE SPARK
DEFECTIVE GAS VALVE
INSUFFICIENT GAS PRESSURE
DEFECTIVE ELECTRICAL HEAT CIRCUIT
Refer to the ladder diagram and the schematics provided with this machine for reference to the above listed information.
ONE BURNER WILL NOT IGNITE DURING A DRYING CYCLE
This condition can be caused by the following:
DEFECTIVE DSI (Direct Spark Ignition) MODULE
DEFECTIVE SPARK
DEFECTIVE GAS VALVE
DEFECTIVE ELECTRICAL HEAT CIRCUIT
LOSS OF GAS PRESSURE
Refer to the ladder diagram and the schematics provided with this machine for reference to the above listed information.