4.Steam Damper Air System Connections

The MLS-410 is manufactured with a pneumatic (piston) damper system which requires an external supply of compressed air. The connection is made at the left hand side on top of the dryer.

a. Air Requirements

Compressed Air Supply

 

Air Pressure

 

 

 

 

Normal

 

80 PSI

5.51 bars

 

 

 

 

Minimum Supply

 

70 PSI

4.82 bars

 

 

 

 

Maximum Supply

 

90 PSI

6.20 bars

 

 

 

 

Shaded areas are stated in metric equivalents

 

 

b.Air Connections

Air connection to system --- 1/8-inch N.P.T.

c.No air regulation is provided with a standard ML-410 dryer. External regulation of 80 PSI (5.512 bars) must be provided. It is suggested that a filter/regulator assembly (with gauge) be added to the compressed air line just before the dryer connection. This is necessary to insure that correct and clean air pressure is achieved. The filter/regulator assembly (with gauge) is provided on dryers with the AUTOMATIC DOOR, TILTING, or SPRINKLER CIRCUIT OPTION.

43

Page 47
Image 47
American Dryer Corp ML-410 manual Steam Damper Air System Connections, Air Requirements