American Dryer Corp ML-79 manual Exhaust Requirements

Models: ML-79

1 49
Download 49 pages 17.54 Kb
Page 18
Image 18

E. EXHAUST REQUIREMENTS

1.General Exhaust Duct Work Information

Exhaust duct work should be designed and installed by a qualified professional. Improperly sized duct work will create excessive back pressure which results in slow drying, increased use of energy, overheating of the dryer, and shutdown of the burner by the airflow (sail) switches, burner hi-limits, or basket (tumbler) hi-heat thermostats.

CAUTION: Dryer must be exhausted to the outdoors.

CAUTION: Improperly sized or installed exhaust dust work can create a potential fire hazard.

The duct work should be laid out in such a way that the duct work travels as directly as possible to the outdoors with as few turns as possible. Single or independent dryer venting is recommended.

When single drying venting is used the length of ductwork from the dryer to the outside exhaust outlet should not exceed fifteen (15) feet. The minimum diameter of the duct work must be at least 10 inches. Even though the dryer exhaust duct for gas and electric units is only 8”. The shape of the duct work is not critical so long as the minimum cross-sectional area is provided. It is suggested that the use of 90º turns be avoided; use 30º or 45º angles instead. The radius of the elbows should preferably be 1-1/2 times the diameter of the duct. Including basket (tumbler) and dryer elbow connections or elbows used for outside protection from the weather, no more than two (2) elbows should be used in the exhaust duct run. If more than two (2) elbows are used, the cross sectional area of the duct work must be increased.

ALL duct work should be smooth inside with no projections from sheet metal screws or other obstructions which will collect lint. When adding ducts, the duct to be added should overlap the duct to which it will connected. ALL duct work joints must be taped to prevent moisture and lint from escaping into the building. The inspection door should be installed at strategic points in the exhaust duct work for periodic inspection and clean-out of lint from the duct work.

IMPORTANT: Exhaust back pressure measured by a manometer in the exhaust duct should not exceed .3 inches of the water column.

IMPORTANT: Minimum duct work diameter is 10 inches.

IMPORTANT: Where the exhaust duct work passes through a wall, ceiling, or roof made of combustible materials, the opening must be 2 inches larger, all the way around, the duct. The duct must be centered within this opening.

a.Outside Duct Work Protection

1.To protect the outside end of horizontal duct work from the weather, a 90º elbow bent downward should be installed where the exhaust exits the building. If the duct work travels vertically up through the roof, it should be protected from the weather by using a 180º turn to point the opening downward. In either case, allow at least twice the diameter of the duct between the duct opening and the nearest obstruction.

IMPORTANT: DO NOT use screens or caps on the outside of opening of exhaust duct work.